Variable: EBRII_PumpDocumentationExample
constEBRII_PumpDocumentationExample:object
Defined in: packages/docs-md/.tmp/typedoc-sanitized/mef-types/lib/data-analysis/example-data-analysis.ts:183
Example of data analysis documentation for EBR-II primary sodium pump
This example demonstrates how to document data analysis for a liquid metal reactor primary sodium pump, with emphasis on documentation requirements (DA-E) and integration with Systems Analysis.
Type Declaration
modelUncertainty
readonlymodelUncertainty:object
Model uncertainty documentation implementing DA-E2 Documents sources of model uncertainty and their impact
modelUncertainty.name
readonlyname:"EBR-II Primary Sodium Pump Model Uncertainty Documentation"="EBR-II Primary Sodium Pump Model Uncertainty Documentation"
modelUncertainty.reasonableAlternatives
readonlyreasonableAlternatives: readonly [{alternative:"Use of Exponential distribution instead of Lognormal for failure rate modeling";applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];reasonNotSelected:"Lognormal better characterizes the uncertainty in the estimated parameters given the limited data"; }, {alternative:"Separate parameter estimates for different operational phases";applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];reasonNotSelected:"Insufficient data to support statistically significant separate estimates"; }]
modelUncertainty.relatedAssumptions
readonlyrelatedAssumptions: readonly [{applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001"];assumption:"EBR-II primary pump reliability characteristics are representative of modern sodium pump designs";basis:"Design principles for electromagnetic sodium pumps have not fundamentally changed, though materials and manufacturing have improved"; }, {applicableParameters: readonly ["PARAM-EBRII-PSP-CCF-001"];assumption:"Common cause failure mechanisms for sodium pumps are similar to those of light water reactor pumps";basis:"While fluid properties differ, fundamental CCF mechanisms like design errors, manufacturing defects, and maintenance errors remain similar"; }]
modelUncertainty.requirementReference
readonlyrequirementReference:"DA-E2"="DA-E2"
modelUncertainty.uncertaintySources
readonlyuncertaintySources: readonly [{applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001","PARAM-EBRII-PSP-FS-001"];impact:"Introduces uncertainty in applicability of parameter estimates to current sodium-cooled fast reactor designs";source:"Operating environment differences between EBR-II and modern liquid metal reactors"; }, {applicableParameters: readonly ["PARAM-EBRII-PSP-FR-001","PARAM-EBRII-PSP-FS-001","PARAM-EBRII-PSP-CCF-001"];impact:"Increases uncertainty in generic data applicability and requires greater reliance on expert judgment";source:"Limited operational history of sodium pumps in commercial power applications"; }]
modelUncertainty.uuid
readonlyuuid:"e87b2c3d-1234-5678-90ab-cdef01234567"="e87b2c3d-1234-5678-90ab-cdef01234567"
preOperationalAssumptions
readonlypreOperationalAssumptions:object
Pre-operational assumptions documentation implementing DA-E3 Documents assumptions made due to limited design or operational data
preOperationalAssumptions.assumptions
readonlyassumptions: readonly [{assumptionId:"ASSUME-EBRII-PSP-001";basis:"Advancements in materials, manufacturing, and control systems are expected to improve reliability";description:"Modern electromagnetic pump designs will have equal or better reliability than EBR-II pumps";impact:"May overestimate failure rates if modern designs prove more reliable";limitations: readonly ["May not account for new failure modes introduced by design innovations","Limited operational experience with newer pump designs"];status:"OPEN"; }, {assumptionId:"ASSUME-EBRII-PSP-002";basis:"Modern maintenance technologies and practices have generally improved over time";description:"Maintenance practices for modern sodium pumps will be at least as effective as those for EBR-II";impact:"May underestimate maintenance-related failures if modern practices prove less effective";limitations: readonly ["Loss of institutional knowledge about sodium pump maintenance","Reduced availability of specialized maintenance personnel"];status:"IN_PROGRESS"; }]
preOperationalAssumptions.name
readonlyname:"EBR-II Primary Sodium Pump Pre-Operational Assumptions"="EBR-II Primary Sodium Pump Pre-Operational Assumptions"
preOperationalAssumptions.relatedNote
readonlyrelatedNote:"DA-N-5"="DA-N-5"
preOperationalAssumptions.relatedRequirement
readonlyrelatedRequirement:"DA-A6"="DA-A6"
preOperationalAssumptions.supportingDocumentationReferences
readonlysupportingDocumentationReferences: readonly ["EBR-II Operational History Report OHR-1994-001","Modern Sodium Pump Design Comparison Study MSPD-2023-001"]
preOperationalAssumptions.uuid
readonlyuuid:"f9876543-21ab-cdef-4321-fedcba098765"="f9876543-21ab-cdef-4321-fedcba098765"
preOperationalAssumptions.validationPhase
readonlyvalidationPhase:"Early operational testing"="Early operational testing"
processDocumentation
readonlyprocessDocumentation:object
Basic documentation structure implementing DA-E1 requirements
processDocumentation.basicEventProbabilityModels
readonlybasicEventProbabilityModels: readonly [{basicEventId:"BE-EBRII-PSP-FR-001";justification:"Lognormal distribution selected based on industry standard practices for continuous operation components with multiplicative failure mechanisms";model:"LOGNORMAL"; }, {basicEventId:"BE-EBRII-PSP-FS-001";justification:"Beta distribution selected for demand-based failure mode to properly model uncertainty with limited data";model:"BETA"; }]
Basic event probability models (DA-E1.b) Documents how basic event probabilities are evaluated
processDocumentation.bayesianPriorRationales
readonlybayesianPriorRationales: readonly [{parameterId:"PARAM-EBRII-PSP-FR-001";priorDistribution:"Lognormal(μ=-11.51, σ=1.5)";rationale:"Prior based on generic liquid metal pump failure rates with wide uncertainty to accommodate limited industry experience"; }]
Bayesian prior rationales (DA-E1.h) Documents selection of prior distributions for Bayesian updates
processDocumentation.ccfProbabilityBasis
readonlyccfProbabilityBasis: readonly [{ccfParameterId:"PARAM-EBRII-PSP-CCF-001";estimationMethod:"Alpha Factor Model with specialized adjustment for liquid metal environment";mappingJustification:"Alpha factors derived from light water reactor experience adjusted for liquid metal environment based on expert judgment"; }]
CCF probability basis (DA-E1.g) Documents basis for common cause failure probability
processDocumentation.componentGroupingDocumentation
readonlycomponentGroupingDocumentation: readonly [{groupId:"GROUP-EBRII-PUMPS-001";groupingCriteria:"Primary sodium pumps grouped based on similar design, operational characteristics, and environment";outlierExclusionJustifications: readonly [{alternativeTreatment:"Analyzed as separate component with its own failure parameters";componentId:"COMP-EBRII-PSP-003";detailedJustification:"Secondary loop pump operates at lower temperature and has different seal design, resulting in significantly different failure characteristics";exclusionReason:"Significant design differences and operating conditions"; }];outlierIdentificationMethodology:"Statistical hypothesis testing comparing failure rates across similar components with 95% confidence threshold";supportingAnalyses: readonly ["EBR-II Pump Similarity Analysis Report PSAR-2022-001"]; }]
Component grouping documentation (DA-B1, DA-B2) Documents component grouping decisions including outlier handling
processDocumentation.dataCollectionPeriods
readonlydataCollectionPeriods: readonly [{censoringJustification:"Pre-1980 data excluded due to major design modifications to pump control systems";endDate:"1994-12-31";parameterId:"PARAM-EBRII-PSP-FR-001";startDate:"1980-01-01"; }]
Time periods for data collection (DA-E1.e) Documents specific time periods and any censoring
processDocumentation.dataExclusionJustifications
readonlydataExclusionJustifications: readonly [{excludedData:"Three failure events during special testing operations in 1983";justification:"Events occurred during non-standard operating conditions not representative of normal operation";parameterId:"PARAM-EBRII-PSP-FR-001"; }]
Data exclusion justification (DA-E1.f) Documents reasons for excluding certain data points
processDocumentation.genericParameterRationales
readonlygenericParameterRationales: readonly [{operatingStates: readonly ["POS-STARTUP-200","POS-SHUTDOWN-300"];parameterId:"PARAM-EBRII-PSP-FS-001";rationale:"Generic parameters used for startup and shutdown states due to insufficient plant-specific data for these infrequent operating states"; }]
Generic parameter rationales (DA-E1.k) Documents rationale for using generic parameter estimates
processDocumentation.genericParameterSources
readonlygenericParameterSources: readonly [{parameterId:"PARAM-EBRII-PSP-FR-001";reference:"Section 5.4, with adjustments for liquid metal reactor applications";source:"NUREG/CR-6928, Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants"; }, {parameterId:"PARAM-EBRII-PSP-FS-001";reference:"LMFR-RDB-2023, Section 4.2.1";source:"Liquid Metal Fast Breeder Reactor Reliability Database (LMFR-RDB)"; }]
Generic parameter sources (DA-E1.c) Documents sources for generic parameter estimates
processDocumentation.name
readonlyname:"EBR-II Primary Sodium Pump Data Analysis Documentation"="EBR-II Primary Sodium Pump Data Analysis Documentation"
processDocumentation.operatingStateDataJustifications
readonlyoperatingStateDataJustifications: readonly [{justification:"Full power operation provides most representative conditions for primary pump failure rates as pumps operate at design flow rates and temperatures";operatingState:"POS-FULL-POWER-100";parameterId:"PARAM-EBRII-PSP-FR-001"; }]
Operating state data justification (DA-E1.j) Documents justification for operating state data usage
processDocumentation.parameterEstimates
readonlyparameterEstimates: readonly [{estimate:0.000012;parameterId:"PARAM-EBRII-PSP-FR-001";uncertaintyCharacterization:"Lognormal distribution with 5th percentile 2.5e-6, 95th percentile 5.8e-5, error factor 4.8"; }, {estimate:0.0034;parameterId:"PARAM-EBRII-PSP-FS-001";uncertaintyCharacterization:"Beta distribution with α=2.5, β=732, 5th percentile 6.7e-4, 95th percentile 8.2e-3"; }]
Parameter estimates with uncertainty (DA-E1.i) Documents final parameter estimates and their uncertainty
processDocumentation.plantSpecificDataSources
readonlyplantSpecificDataSources: readonly [{operatingState:"POS-FULL-POWER-100";parameterId:"PARAM-EBRII-PSP-FR-001";source:"EBR-II Operational Records 1964-1994";timePeriod:"1980-1994"; }]
Plant-specific data sources (DA-E1.d) Documents plant-specific data sources used
processDocumentation.systemComponentBoundaries
readonlysystemComponentBoundaries: readonly [{boundaries: readonly ["Electromagnetic pump assembly","Control circuitry","Power supply components","Primary flow path components"];boundaryDescription:"EBR-II primary sodium pump including motor, pump, shaft, bearings, and seals";componentId:"COMP-EBRII-PSP-001";references: readonly ["EBR-II System Design Description SDD-PCS-001","EBR-II Primary Pump Drawing E-12345-001"];systemId:"SYS-EBRII-PCS-001"; }]
System and component boundaries (DA-E1.a) References a SystemDefinition from Systems Analysis
processDocumentation.uuid
readonlyuuid:"dd72a844-ff75-4517-86a4-5e4bfc7c0384"="dd72a844-ff75-4517-86a4-5e4bfc7c0384"
Example
// Access the example
import { examples } from 'data_analysis';
const pumpDocumentation = examples.EBRII_PumpDocumentationExample;